Table 3 Comparison of both single-input and multi-input models

From: An artificial intelligence-enabled ECG algorithm for identifying ventricular premature contraction during sinus rhythm

Data type

Model

Acc

ROC AUC

Sensitivity

Specificity

Time series

ResNet50V2 (Single-input)

0.840

0.889

0.886

0.804

Time series

ResNet50V2 (Multi-input)

0.880

0.929

0.896

0.865

  1. Acc accuracy, ROC AUC area under the receiver operating characteristic curve, VPC ventricular premature complex